Mc evolution - upper arm blood pressure monitor
Estimated delivery: 1-3 business days
Information on returns and shipments
Payment methods
The Mc Evolution Upper Arm Blood Pressure Monitor is a medical device that uses the oscillometric method to monitor and display diastolic and systolic blood pressure and heart rate in adults.
Indications
The monitor uses the oscillometric method to measure blood pressure.
The automatic electronic blood pressure monitor is intended for use by medical professionals or at home to monitor and display diastolic and systolic blood pressure and heart rate in adults.
| Measurement Method | Oscillometric Measurement |
| Indicator | Digital LED Display |
| Measuring Range | Blood Pressure: 30-280 mmHg Heart Rate: 40-199 beats/minute |
| Accuracy | Static Blood Pressure: ±3 mmHg Pulse: ±5% |
| Memory | 90 measurements |
| Power supply | 4 x 1.5 V batteries (LR03 or AAA) |
| Operating conditions | Temperature: 5°C to 40°C Humidity: Relative humidity: 15-93% Atmospheric pressure: 70-106 kPa |
| Storage conditions | Temperature: -20°C to +55°C Humidity: Relative: 0-93% Atmospheric pressure: 50-106 kPa |
| Dimensions | approximately 93 mm (W) x 161 mm (H) x 47 mm (D) |
| Classification | Type Bf |
| Upper arm circumference | 22-32 cm |
| Mode Operation | Continuous operation |
| AC adapter | Input: 100-240 V, 50/60 Hz, 0.2 A Output: 6 V 500 mA |
How to use
Inserting or replacing batteries
Remove the battery cover. Insert new batteries into the battery compartment, making sure the polarity is correct. Close the battery cover. Use only LR03 or AAA batteries.
When the low battery indicator flashes on the display, replace the batteries.
Do not mix old and new batteries. This may shorten battery life or cause the device to malfunction.
Use only the specified batteries. The batteries supplied with the device are for testing the monitor's performance and may have a shorter life.
Replace worn batteries with their polarities facing the correct way.
If you will not be using the unit for a long period of time (about three months or more), remove the batteries.
Attaching the Cuff to the Arm
Wrap the cuff around your upper arm, about 2-3 cm above the elbow. Place the cuff directly on the skin, as clothing can cause a weak pulse and subsequent measurement error.
Constriction of the upper arm, caused by rolling up a shirt or blouse sleeve, can cause a weak pulse and result in measurement errors. prevent accurate readings.
Secure the cuff with the Velcro strip so that it is comfortable and not too tight. Rest your arm on the table (palm up) so that the cuff is at the same height as your heart. Make sure the tube is not kinked.
Blood Pressure Measurement
To measure your blood pressure, sit comfortably without crossing your legs, with your feet flat on the floor. Remain still and quiet during the measurement.
Press the On/Off button, all icons appear on the display for two seconds, then switch to measurement and display '0' or the last measurement record. Start the measurement, the cuff will inflate automatically. The heart symbol will flash on the LED. Once the measurement is complete, the results will appear on the display.
Measure your blood pressure at approximately the same time every day.
Do not measure immediately after exercise or bathing. Rest for twenty to thirty minutes before taking a measurement.
Cleaning and Maintenance
Clean the monitor with a soft, dry cloth. Do not use any cleaning solution.
Do not immerse the device or any component in water.
Clean the cuff after each use. Wipe the inside (skin contact) of the cuff thoroughly with a soft cloth lightly moistened with 75% ethyl alcohol three times. Replace the soft cloth after each wipe. Then air dry the cuff.
Interactions
Measurements may be affected if this device is used near televisions, microwave ovens, X-ray equipment, cell phones, or other devices with strong electric fields. To avoid such interference, use the monitor at a sufficient distance from such devices or turn them off.
Do not measure on the arm that was simultaneously used with the Me equipment monitoring, otherwise it may cause loss of functionality.
Warnings
If you are taking medication, consult your doctor to determine the most appropriate time to measure your blood pressure. Never change a prescribed medication without first consulting your doctor.
For people with irregular or unstable peripheral circulation due to diabetes, liver disease, hardening of the arteries, etc., there may be fluctuations in blood pressure values measured at the upper arm compared to the wrist.
Before use, wash your hands.
Batteries that have liquid on their surface or have been modified cannot be inserted into the products.
Short-circuiting the battery should be avoided.
Battery life varies with ambient temperature and may be reduced at low temperatures.
Do not immerse the device or any other Do not immerse any of the components in water.
Do not expose the monitor to extremely hot or cold temperatures, humidity, or direct sunlight.
Do not subject the monitor to strong>severe shock.
Storage
Temperature: -20°C to +55°C
Relative humidity: 0-93%
Atmospheric pressure: 50-106 kPa
Price Trend
This product has been on sale since 20/02/2026
In the last 30 days, the product's lowest price was 36,75 €