Free shipping from 69,00 € and always free returns

Candida screen test - rapid self-diagnosis test

(0)
Productor: Screen italia
Rapid test for the detection and self-diagnosis of Candida.
info prodotto Richiedi info sul prodotto

Estimated delivery: 1-3 business days

This product earns 8 POINTS
-29,67%
€16.10
Recommended price €22.90
Extra quantity discount
from 5 Pieces You're saving: 1,00%
from 10 Pieces You're saving: 2,00%
This product earns 8 POINTS
info resi e spedizione

Information on returns and shipments

info pagamenti

Payment methods

99& satisfied customers
Product Description

Screen Test Candida is a rapid qualitative self-test capable of detecting the presence of Candida antigens in vaginal secretions collected via swab.

Indications

Rapid qualitative self-test capable of detecting the presence of Candida antigens in vaginal secretions collected via swab.

The test is based on the immunochromatographic method. The swab sample is added to the sample pad through the cap containing the dilution buffer. From there, the sample migrates to the conjugate pad, releasing anti-Candida antibodies conjugated to blue-colored latex particles. The Candida antigen-antibody conjugate complex formed continues to move to the nitrocellulose membrane strip. The complex is then captured on the support membrane by immobilized anti-Candida antibodies, generating a signal line.

If Candida antigen is present in the swab sample, a biological reaction will occur and the result will be positive. A blue line will appear in the test line region (T) on the membrane.

The test includes a built-in control system, represented by the control line (C). The control line confirms that the test has been performed correctly.

Instructions for Use

Leave the test cassette at room temperature (between 15°C and 27°C) before performing the procedure.

Open the test kit only when you are ready to perform the procedure. Do not use the test if the pouch is damaged. Have a watch/stopwatch available.

Make sure the surface on which the procedure will be performed is clean. Wash your hands. The test can be performed at any time of day.

Remove the device from the sealed pouch and place it horizontally on a flat surface. Hold the device steady with one hand. With the other hand, gently remove the foil seal from the purple cap. The purple cap contains a liquid.

Remove the stick from the pouch. Insert the swab about 2 cm into the vagina and rotate for 20 seconds. Gently remove the swab.

Rotate the swab in the liquid in the purple cap for 20 seconds. Gently remove the swab, pressing it against the inside wall of the purple cap. Discard the swab.

Hold the device steady with one hand. Rotate the purple cap counterclockwise until it stops, then rotate it counterclockwise until it starts. Repeat this step two more times. At the end point, the notches on the purple cap should align with the indentation on the white base.

Read the results after 10 minutes.

Interpreting Results

Positive: A blue line appears at the control line (C) and an additional blue line appears at the test line (T).

The test result indicates that Candida antigens are present in the vaginal secretions. Contact a doctor to confirm the result and initiate treatment.

Negative: Only a blue line appears at the control line (C) and no blue line appears at the test line (T).

The test result indicates that Candida antigens are not present in the vaginal secretions. If symptoms or discomfort persist, it is recommended that you consult a doctor.

Invalid: If neither line appears or only the test line (T) appears, the test result cannot be interpreted. You must perform a new test, following the instructions carefully.

Warnings

For in vitro diagnostic use only.

Do not insert inside the body.

The test is not reusable.

The test only works if the instructions are carefully followed.

A negative test result does not rule out other infections. Contact your doctor.

Suitable only for women aged 18 years and over.

Do not use after the expiration date printed on the foil pouch.

Keep out of reach of children.

Dispose of the device and the test stick with normal household waste.

Do not use the test stick if it falls on the floor.

Do not use the test components if they are broken.

Do not use if liquid leaks from the cap. The amount of liquid inside the cap is crucial to ensuring the test works properly.

Do not twist the cap before removing the seal or inserting the test stick. Rotating the upper part of the device has an irreversible effect, as the test will no longer be Valid.

Contraindications

The test should not be used during menstruation.

Do not use during pregnancy.

Do not use the test within 7 days of taking medications for vaginal infections.

Do not use the test within 24 hours of using creams, gels, foams, douches, or other intimate hygiene products.

Pregnancy and breastfeeding

Do not use during pregnancy.

Storage

Store in a dry place at room temperature (between 2°C and 30°C). °C).

Shelf life when package is intact: 24 months.

Format

The kit contains:

  • 1 test cassette;
  • 1 sterile test stick;
  • 1 instruction sheet for use;
  • 1 translated information sheet.
Product Code:FRCM234313

Price Trend

This product has been on sale since 30/12/2025

In the last 30 days, the product's lowest price was 16,1 €

5% EXTRA DISCOUNT on FIRST ORDER! Register and discover the WELCOME Coupon!
To enhance your website experience, Farmacosmo.com uses different types of cookies. You can click OK, to allow them, or manage them individually. By clicking on the ''x'' you don't accept any cookies and other tracking methods other than technical ones. To read more see our Cookie Policy. Cookie Policy